Produkty

Huawei FusionServer RH2288 V3 Rack Server

Idealny balans pomiędzy wydajnością, pojemnością a gęstością upakowania. Serwer 2U, dwuprocesorowy.

    Zapytaj o

    Huawei FusionServer RH2288 V3 Rack Server

    Opis produktu Huawei FusionServer RH2288 V3 Rack Server

    Offers large storage capacity, flexible resource expansion, and high computing performance. The Huawei RH2288 V3 is an ideal choice for Internet, Big Data, cloud computing, telecom services, and key enterprise applications.

    This 2U rack server can include two Intel® Xeon® E5-2600 v3/v4 processors. Up to 16 DDR4 DIMMs, and the rack accommodates 16 3.5-inch hard disks or 28 2.5-inch hard disks. Up to 6 PCIe 3.0 slots, and the slot accommodates dual-slot GPUs. I/O performance surpasses that of hard disks when used with Huawei PCIe SSD cards and NVMe SSDs.

    The RH2288 V3 balances performance and density in a 2U space.

    • Large local storage space enables quick scalability for dealing with increases in data volumes
    • Intelligent, fine-grained power control technologies (including Dynamic Energy Management Technology; allocation of cooling and power supply resources on demand; and Proportional Integration Differentiation to control heat dissipation and speed adjustments) ensure high energy efficiency
    • A data recorder helps locate any faults that cause a server crash
    • A LED panel enables local management, while an independent iBMC module implements Serial over LAN (SoL), remote KVM, and other functions

    Specyfikacja techniczna

    Processor Intel® Xeon® E5-2600 v3/v4 series processors
    Memory 16 DDR4 RDIMMs/LRDIMMs
    Internal Storage Hard disk configurations:

    • 8 x 2.5-inch SAS/SATA HDDs or SSDs
    • 10 x 3.5-inch SATA HDDs
    • 12 x 3.5-inch front SAS/SATA HDDs (4 NVMe SSDs supported by the NVMe model) and 2 rear hard disk modules, each module providing 2 x 2.5-inch SAS/SATA HDDs or SSDs, or 2 x 3.5-inch SAS/SATA HDDs
    • 25 x 2.5-inch front SAS/SATA HDDs or SSDs and 2 or 3 x 2.5-inch rear SAS/SATA HDDs or SSDs
    RAID
    • RAID 0, 1, 10, 5, 50, 6, or 60
    • Configured with a supercapacitor for power-off protection for the cache (optional)
    • RAID state transition, configuration memory, self-diagnosis, and web-based remote configuration
    LOM Network Ports 2 GE or 4 GE ports, or 2 x 10 GE ports, or 2 x 56 Gbit/s FDR InfiniBand ports
    PCIe Expansion Up to 6 PCIe 3.0 slots
    Fan Modules Hot-swappable fan modules in N+1 redundancy mode
    Power Supply Units 2 hot-swappable PSUs in 1+1 redundancy mode
    Management
    • Uses the Huawei Hi1710 management chip and independent ports
    • Supports standard management interfaces, such as SNMP and IPMI; provides GUI, remote KVM, virtual media, SOL, Predictive Failure Analysis (PFA), intelligent power supply, remote control, and hardware monitoring
    • Supports Huawei eSight management software and integration with third-party management systems, such as VMware vCenter, Microsoft System Center, and Nagios
    Operating Temperature 5°C to 45°C (41°F to 113°F), ASHRAE Class A3 and A4 compliant

     

    RH2288H

    Processors Intel® Xeon® E5-2600 v3/v4 series processors
    Memory 24 DDR4 RDIMMs/LRDIMMs
    Internal Storage Hard disk configurations:

    • 8 x 2.5-inch front SAS/SATA HDDs or SSDs
    • 10 x 3.5-inch front SATA HDDs
    • 12 x 3.5-inch front SAS/SATA HDDs (4 NVMe SSDs supported by the NVMe model) and 2 rear hard disk modules, each module providing 2 x 2.5-inch SAS/SATA HDDs or SSDs, or 2 x 3.5-inch SAS/SATA HDDs
    • 25 x 2.5-inch front SAS/SATA HDDs or SSDs and 2 or 3 x 2.5-inch rear SAS/SATA HDDs or SSDs

    Built-in flash memory:

    • 2 mini-SSD cards (SATADOMs)
    • 2 SD cards
    RAID
    • RAID 0, 1, 10, 5, 50, 6, or 60
    • Configured with a supercapacitor for power-off protection for the cache (optional)
    • RAID state transition, configuration memory, self-diagnosis, and web-based remote configuration
    LOM Network Ports 2 GE or 4 GE ports, or 2 x 10 GE ports, or 2 x 56 Gbit/s FDR InfiniBand ports
    PCIe Expansion Up to 9 PCIe 3.0 slots
    Fan Modules Hot-swappable fan modules in N+1 redundancy mode
    Power Supply Units 2 hot-swappable PSUs in 1+1 redundancy mode
    Management
    • Uses the Huawei Hi1710 management chip and independent ports
    • Supports standard management interfaces, such as SNMP and IPMI; provides GUI, remote KVM, virtual media, SOL, Predictive Failure Analysis (PFA), intelligent power supply, remote control, and hardware monitoring
    • Incorporates a touchscreen LCD panel for fault diagnosis
    • Supports Huawei eSight management software and integration with third-party management systems, such as VMware vCenter, Microsoft System Center, and Nagios
    Operating Temperature 5°C to 45°C (41°F to 113°F), ASHRAE Class A3 and A4 compliant

     