Moduły OTDR CWDM z serii 4100
VIAVI 4100-Series CWDM OTDR Modules
For T-BERD®/MTS-2000, −4000, −5800 Platforms
Connect the VIAVI Solutions™ 4100-Series CWDM OTDR family to successfully deploy and maintain
C-RAN, DAS, CWDM, and fronthaul networks. CWDM OTDR-family optical performance, combined with the T-BERD/MTS platform’s suite of testing features, ensures that testing jobs are performed right—the first time.
Testing features include:
Benefits
Features
Applications
Moduły OTDR CWDM z serii 4100 to idealny wybór dla utrzymania i rozwoju sieci C-RAN, DAS, CWDM.
Laser safety | Class 1 (IEC), Class 1 (21CFR) |
Weight | 430g (0.95 lb) |
Dimensions (w x h x d) | 128 x 134 x 40 mm
(5 x 5.28 x 1.58 in) |
Distance Units | Km/m/mile/ft |
Group index range | 1.30000 to 1.70000
in 0.00001 steps |
Number of data points | Up to 256,000 data points |
Distance Measurements | |
Mode | Automatic or dual cursor |
Display range | From 0.5 up to 260 km |
Display resolution | 1 cm |
Cursor resolution | From 1 cm |
Sampling resolution | From 4 cm |
Accuracy | ±1 m ±sampling resolution
±1.10-5 x distance (excluding group index uncertainties) |
Attenuation Measurements | |
Mode | Automatic, manual, 2-point, 5-point and LSA |
Display range | From 1.25 dB to 55 dB |
Display resolution | 0.001 dB |
Cursor resolution | From 0.001 dB |
Attenuation linearity | ±0.03 dB/dB |
Threshold | 0.01 to 1.99 dB in 0.01 dB step |
Reflectance/ORL Measurements | |
Mode | Automatic or manual |
Reflectance accuracy | ±2 dB |
Display resolution | 0.01 dB |
Threshold | –11 to –98 dB in 1 dB steps |
Storage | Bellcore/Telcordia compatible Version 1.1 and Version 2.0 |
OTDR | |
CWDM Wavelengths1 | 1271/1291/1311/1331/1351/1371/1391/
1411/1431/1451/1471/1491/1511/1531/ 1551/1571/1591/1611nm +/-3nm |
Pulsewidth | 10 ns to 20 μs |
Dynamic range2 | 35dB |
Event dead zone3 | 1.5 m |
Attenuation dead zone4 | 5 m |
Continuous Wave Light Source | Wavelengths: same as OTDR |
Output power -3.5 dBm | |
Operating modes5: CW, 270 Hz, 330 Hz, 1 kHz, 2 kHz | |
Automatic traffic detection | Yes |
In-service testing | Yes |